PID Tune
Manual Bed Leveling
Automatic Bed Leveling
Flow Rate Multiplier
Jerk
Acceleration
Retraction
Steps/mm:
Measure 120-150mm of filament from the entry to the extruder.
Heat hotend to desired printing temperature.
Use the Move functionality of the printer to push 100mm of filament through the hotend.
Measure the remaining amount. The extra 20-50 mm of filament is intended to let you easily measure the amount if MORE than the specified 100mm gets fed through the printer.
Go into the Settings for the printer and find the currently set Steps/mm setting.
Use the following formula to calculate new Steps/mm value:
Amount of filament printer was SUPPOSED to feed through the printer divided by the Amount of filament ACTUALLY fed through the printer times the current Steps/mm value.
I just did this on my printer and these are my values:
Amount printer should have fed through the printer: 100mm
Amount of filament fed through the printer: 105mm
Current Steps/mm Value: 110.5
100/105 = .9523
.9523*110.5 = 105.23